Please use this identifier to cite or link to this item: http://dspace.mediu.edu.my:8181/xmlui/handle/10261/4134
Full metadata record
DC FieldValueLanguage
dc.contributorMinisterio de Ciencia y Tecnología (España)-
dc.contributorComunidad de Madrid-
dc.creatorBarea, R.-
dc.creatorMarín Marín, Ricardo-
dc.creatorOsendi, María Isabel-
dc.creatorMartínez, R.-
dc.creatorMiranzo López, Pilar-
dc.date2008-05-12T06:54:07Z-
dc.date2008-05-12T06:54:07Z-
dc.date2006-03-
dc.date.accessioned2017-01-31T01:13:48Z-
dc.date.available2017-01-31T01:13:48Z-
dc.identifierBoletín de la Sociedad Española de Cerámica y Vidrio 45(2): 80-86 (2006)-
dc.identifier0366-3175-
dc.identifierhttp://hdl.handle.net/10261/4134-
dc.identifier.urihttp://dspace.mediu.edu.my:8181/xmlui/handle/10261/4134-
dc.description[ES] Entre las distintas técnicas de medida de la conductividad térmica de materiales, el método comparativo, recogido en la norma ASTM E1225-99, es el más adecuado para muestras porosas o materiales compuestos. Este método permite determinar conductividades térmicas en estado estacionario, en el intervalo de valores de 0,2 a 200 W/mK, y a temperaturas de ensayo en el rango 100-1300 K, dependiendo del diseño del equipo. En este trabajo se expone el diseño, desarrollo y puesta a punto de un equipo de medida de conductividad térmica basado en este método. Paralelamente, se realiza una validación del equipo mediante el estudio comparativo de los resultados obtenidos usando el equipo comparativo y la técnica del pulso láser en materiales porosos de mullita.-
dc.description[EN] Among the different techniques available for measuring thermal conductivity, the comparative method (ASTM E1225-99) is the most appropriate for porous materials. This method determines the thermal conductivity in steady state conditions in the 100 - 1300 K temperature range and for conductivities between 0.2 and 200 W/mK, respectively, depending on the equipment characteristics. In the present paper, the design and development, as well as the start up process, of an apparatus based on this method is described. Thermal conductivity data on a mullite based refractory, measured by both the laser flash and the comparative methods, are presented and comparatively discussed in order to validate the developed equipment.-
dc.descriptionEste trabajo ha sido financiado por los proyectos CAM 07N/0095/2002 y Mcyt, MAT 2003-06147-C04-01.-
dc.descriptionPeer reviewed-
dc.format349529 bytes-
dc.formatapplication/pdf-
dc.languagespa-
dc.publisherSociedad Española de Cerámica y Vidrio-
dc.relationhttp://boletines.secv.es/es/index.php?id=5&vol=45-
dc.rightsopenAccess-
dc.subjectConductividad térmica-
dc.subjectDifusividad térmica-
dc.subjectMétodo comparativo-
dc.subjectMateriales porosos-
dc.subjectMullita-
dc.subjectThermal conductivity-
dc.subjectThermal diffusivity-
dc.subjectComparative method-
dc.subjectPorous materials-
dc.subjectMullite-
dc.titleEquipo comparativo para la medida de conductividad térmica de materiales cerámicos-
dc.titleComparative equipment for the measurement of the thermal conductivity-
dc.typeArtículo-
Appears in Collections:Digital Csic

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.